p.89 抽出テキスト
and cardiac resynchronization therapy: A systematic review and meta-analysis. J Cardiopulm Rehabil Prev 2019; 39: 308-317. PMID: 31397767 361. Rubenstein JJ, Schulman CL, Yurchak PM, et al. Clinical spectrum of the sick sinus syndrome. Circulation 1972; 46: 5- 13. PMID: 5039825 362. Jensen PN, Gronroos NN, Chen LY, et al. Incidence of and risk factors for sick sinus syndrome in the general population. J Am Coll Cardiol 2014; 64: 531-538. PMID: 25104519 363. Daley WR, Kaczmarek RG. The epidemiology of cardiac pacemakers in the older US population. J Am Geriatr Soc 1998; 46: 1016-1019. PMID: 9706894 364. Anderson JB, Benson DW. Genetics of sick sinus syndrome. Card Electrophysiol Clin 2010; 2: 499-507. PMID: 21499520 365. Benson DW, Wang DW, Dyment M, et al. Congenital sick sinus syndrome caused by recessive mutations in the cardiac sodium channel gene (SCN 5A). J Clin Invest 2003; 112: 1019- 1028. PMID: 14523039 366. Hayashi H, Sumiyoshi M, Nakazato Y, et al. Brugada syndrome and sinus node dysfunction. J Arrhythm 2018; 34: 216- 221. PMID: 29951135 367. Morita H, Fukushima-Kusano K, Nagase S, et al. Sinus node function in patients with Brugada-type ECG. Circ J 2004; 68: 473-476. PMID: 15118291 368. Sumiyoshi M, Nakazato Y, Tokano T, et al. Sinus node dysfunction concomitant with Brugada syndrome. Circ J 2005; 69: 946- 950. PMID: 16041164 369. Lauer MS. Chronotropic incompetence: Ready for prime time. J Am Coll Cardiol 2004; 44: 431-432. PMID: 15261943 370. Gann D, Tolentino A, Samet P. Electrophysiologic evaluation of elderly patients with sinus bradycardia: A long-term follow-up study. Ann Intern Med 1979; 90: 24-29. PMID: 420459 371. Aste M, Brignole M. Syncope and paroxysmal atrioventricular block. J Arrhythm 2017; 33: 562-567. PMID: 29255501 372. Kusumoto FM, Schoenfeld MH, et al. 2018 ACC/AHA/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. Heart Rhythm 2019; 16: e 128-e 226. PMID: 30412778 373. Carroz P, Delay D, Girod G. Pseudo-pacemaker syndrome in a young woman with first-degree atrio-ventricular block. Europace 2010; 12: 594-596. PMID: 19946114 374. Inoue H, Fujiki A, Origasa H, et al. Prevalence of atrial fibrillation in the general population of Japan: An analysis based on periodic health examination. Int J Cardiol 2009; 137: 102-107. PMID: 18691774 375. Akao M, Chun YH, Wada H, et al. Fushimi AF Registry Investigators. Current status of clinical background of patients with atrial fibrillation in a community-based survey: The Fushimi AF Registry. J Cardiol 2013; 61: 260-266. PMID: 23403369 376. Schnabel RB, Sullivan LM, Levy D, et al. Development of a risk score for atrial fibrillation (Framingham Heart Study): a communitybased cohort study. Lancet 2 0 0 9 ; 3 7 3 : 7 3 9 - 7 4 5 . PMID: 19249635 377. Huxley RR, Lopez FL, Folsom AR, et al. Absolute and attributable risks of atrial fibrillation in relation to optimal and borderline risk factors: The Atherosclerosis Risk in Communities (ARIC) study. Circulation 2011; 123: 1501-1508. PMID: 21444879 378. Barnett K, Mercer SW, Norbury M, et al. Epidemiology of multimorbidity and implications for health care, research, and medical education: a cross-sectional study. Lancet 2012; 380: 37- 43. PMID: 22579043 379. Alonso A, Krijthe BP, Aspelund T, et al. Simple risk model predicts incidence of atrial fibrillation in a racially and geographically diverse population: the CHARGE-AF consortium. J Am Heart Assoc 2013; 2: e000102. PMID: 23537808 380. Kokubo Y, Watanabe M, Higashiyama A, et al. Development of a basic risk score for incident atrial fibrillation in a Japanese general population: The Suita Study. Circ J 2017; 81: 1580- 1588. PMID: 28539563 381. Haïssaguerre M, Jaïs P, Shah DC, et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med 1998; 339: 659-666. PMID: 9725923 382. Wijffels MC, Kirchhof CJ, Dorland R, et al. Atrial fibrillation begets atrial fibrillation. A study in awake chronically instrumented goats. Circulation 1995; 92: 1954-1968. PMID: 7671380 383. Nattel S, Burstein B, Dobrev D. Atrial remodeling and atrial fibrillation: Mechanisms and implications. Circ Arrhythm Electrophysiol 2008; 1: 62-73. PMID: 19808395 384. Kirchhof P, Benussi S, Kotecha D, et al. 2016 ESC guidelines for the management of atrial fibrillation developed in collaboration with EACTS. Eur Heart J 2016; 37: 2893- 2962. PMID: 27567408 385. Steinberg JS, O’Connell H, Li S, et al. Thirty-second gold standarddDefinition of atrial fibrillation and its relationship with subsequent arrhythmia patterns: Analysis of a large prospective device database. Circ Arrhythm Electrophysiol 2 0 1 8 ; 11 : e006274. PMID: 30002065 386. Calkins H, Hindricks G, Cappato R, et al. 2017 HRS/EHRA/ ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm 2017; 14: e275-e444. PMID: 28506916 387. Ikemura N, Spertus JA, Kimura T, et al. Cohort profile: patient characteristics and quality-of-life measurements for newlyreferred patients with atrial fibrillation - Keio interhospital Cardiovascular Studies-atrial fibrillation (KiCS-AF). BMJ Open 2019; 9: e032746. PMID: 31857312 388. Esato M, Chun YH, An Y, et al. Clinical Impact of asymptomatic presentation status in patients with paroxysmal and sustained atrial fibrillation: The Fushimi AF Registry. Chest 2017; 152: 1266-1275. PMID: 28823813 389. Pollak WM, Simmons JD, Interian A Jr, et al. Clinical utility of intraatrial pacemaker stored electrograms to diagnose atrial fibrillation and flutter. Pacing Clin Electrophysiol 2001; 24: 424-429. PMID: 11341078 390. Kohno R, Abe H, Oginosawa Y, et al. Reliability and characteristics of atrial tachyarrhythmias detection in dual chamber pacemakers. Circ J 2011; 75: 1090-1097. PMID: 21436592 391. Kaufman ES, Israel CW, Nair GM, et al. ASSERT Steering Committee and Investigators. Positive predictive value of devicedetected atrial high-rate episodes at different rates and durations: An analysis from ASSERT. Heart Rhythm 2012; 9: 1241-1246. PMID: 22440154 392. Jaakkola J, Vasankari T, Virtanen R, et al. Reliability of pulse palpation in the detection of atrial fibrillation in an elderly population. Scand J Prim Health Care 2017; 35: 293- 298. PMID: 28784027 393. Virtanen R, Kryssi V, Vasankari T, et al. Self-detection of atrial fibrillation in an aged population: the LietoAF Study. Eur J Prev Cardiol 2014; 21: 1437-1442. PMID: 23780517 394. Jaakkola J, Virtanen R, Vasankari T, et al. Self-detection of atrial fibrillation in an aged population: three-year follow-up of the LietoAF intervention study. BMC Geriatr 2017; 17: 218. PMID: 28915862 395. Cooke G, Doust J, Sanders S. Is pulse palpation helpful in detecting atrial fibrillation? A systematic review. J Fam Pract 2006; 55: 130-134. PMID: 16451780 396.Lowres N, Neubeck L, Redfern J, et al. Screening to identify unknown atrial fibrillation: A systematic review. Thromb Haemost 2013; 110: 213-222. PMID: 23595785 397. Taggar JS, Coleman T, Lewis S, et al. Accuracy of methods for detecting an irregular pulse and suspected atrial fibrillation: A systematic review and meta-analysis. Eur J Prev Cardiol 2016; 23: 1330-1338. PMID: 26464292 398. Verberk WJ, Omboni S, Kollias A, et al. Screening for atrial fibrillation with automated blood pressure measurement: Research evidence and practice recommendations. Int J Cardiol 2016; 203: 465-473. PMID: 26547741 399. Kane SA, Blake JR, McArdle FJ, et al. Opportunistic detection of atrial fibrillation using blood pressure monitors: a systematic review. Open Heart 2016; 3: e000362. PMID: 27099760 400. Rozen G, Vaid J, Hosseini SM, et al. Diagnostic accuracy of a novel mobile phone application for the detection and monitoring of atrial fibrillation. Am J Cardiol 2018; 121: 1187- 1191. PMID: 29525063 401. Brasier N, Raichle CJ, Dörr M, et al. Detection of atrial fibrillation with a smartphone camera: first prospective, international, two-centre, clinical validation study (DETECT AF PRO). Europace 2019; 21: 41-47. PMID: 30085018 402. Halcox JPJ, Wareham K, Cardew A, et al. Assessment of remote heart rhythm sampling using the AliveCor Heart Monitor to screen for atrial fibrillation: The REHEARSE-AF Study. Circulation 2017; 136: 1784-1794. PMID: 28851729 403. Aizawa Y, Takatsuki S, Suenaga Y, et al. Diagnostic value of portable electrocardiogram (Cardiophone) in patients complaining of palpitation. Int J Cardiol 2013; 168: 2925-2927. PMID: 23643440 404. Ramkumar S, Nerlekar N, D’Souza D, et al. Atrial fibrillation