GL検索 v0.1.0
画像は 65 ページを描画したものです
page 65

p.65 抽出テキスト

Ann Thorac Surg 1998; 66: 1829-1830. PMID: 9875810 266. Schlensak C, Schibilsky D, Siepe M, et al. Biventricular cannulation is superior regarding hemodynamics and organ recovery in patients on biventricular assist device support. J Heart Lung Transplant 2011; 30: 1011-1017. PMID: 21489816 267. Fukui S, Matsumiya G, Toda K, et al. Recovery from hemorrhagic pulmonary damage by combined use of a left ventricular assist system and right ventricular assist system and extracorporeal membrane oxygenation. J Heart Lung Transplant 2006; 25: 248-250. PMID: 16446230 268. Anderson MB, Goldstein J, Milano C, et al. Benefits of a novel percutaneous ventricular assist device for right heart failure: The prospective RECOVER RIGHT study of the Impella RP device. J Heart Lung Transplant 2015; 34: 1549-1560. PMID: 26681124 269. Sorensen EN, Pierson RN 3rd, Feller ED, et al. University of Maryland surgical experience with the Jarvik 2000 axial flow ventricular assist device. Ann Thorac Surg 2012; 93: 133-140. PMID: 22112796 270. Morshuis M, El-Banayosy A, Arusoglu L, et al. European experience of DuraHeartTM magnetically levitated centrifugal left ventricular assist system. Eur J Cardiothorac Surg 2009; 35: 1020-1028. PMID: 19233673 271. Cleveland JC Jr, Naftel DC, Reece TB, et al. Survival after biventricular assist device implantation: an analysis of the Interagency Registry for Mechanically Assisted Circulatory Support database. J Heart Lung Transplant 2011; 30: 862-869. PMID: 21621423 272. Fitzpatrick JR 3rd, Frederick JR, Hiesinger W, et al. Early planned institution of biventricular mechanical circulatory support results in improved outcomes compared with delayed conversion of a left ventricular assist device to a biventricular assist device. J Thorac Cardiovasc Surg 2009; 137: 971-977. PMID: 19327526 273. Matthews JC, Koelling TM, Pagani FD, et al. The right ventricular failure risk score: A pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates. J Am Coll Cardiol 2008; 51: 2163-2172. PMID: 18510965 274. Kormos RL, Teuteberg JJ, Pagani FD, et al. HeartMate II Clinical Investigators. Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes. J Thorac Cardiovasc Surg 2010; 139: 1316- 1324. PMID: 20132950 275. Shiga T, Kinugawa K, Imamura T, et al. Combination evaluation of preoperative risk indices predicts requirement of biventricular assist device. Circ J 2012; 76: 2785-2791. PMID: 22878403 276. Samura T, Yoshioka D, Asanoi H, et al. Right atrial pressure waveform predicts right ventricular failure after left ventricular assist device implantation. Ann Thorac Surg 2019; 108: 1361-1368. PMID: 31175868 277. Lazar JF, Swartz MF, Schiralli MP, et al. Survival after left ventricular assist device with and without temporary right ventricular support. Ann Thorac Surg 2013; 96: 2155-2159. PMID: 24035303 278. Vierecke J, Gahl B, de By TMMH, et al. Results of primary biventricular support: an analysis of data from the EUROMACS registry. Eur J Cardiothorac Surg 2019; 56: 1037-1045. PMID: 31369075 279. Saito S, Sakaguchi T, Sawa Y. Clinical report of long-term support with dual Jarvik 2000 biventricular assist device. J Heart Lung Transplant 2011; 30: 845-847. PMID: 21459618 280. Krabatsch T, Potapov E, Stepanenko A, et al. Biventricular circulatory support with two miniaturized implantable assist devices. Circulation 2011; 124 Suppl: S179-S186. PMID: 21911810 281. Horton SC, Khodaverdian R, Chatelain P, et al. Left ventricular assist device malfunction: an approach to diagnosis by echocardiography. J Am Coll Cardiol 2005; 45: 1435-1440. PMID: 15862415 282. Catena E, Milazzo F, Montorsi E, et al. Left ventricular support by axial flow pump: the echocardiographic approach to device malfunction. J Am Soc Echocardiogr 2005; 18: 1422.e7-e13. PMID: 16376778 283. Cohn WE, Gregoric ID, Frazier OH. Reinforcement of left ventricular assist device outflow grafts to prevent kinking. Ann Thorac Surg 2007; 84: 301-302. PMID: 17588447 284. Goldstein DJ, John R, Salerno C, et al. Algorithm for the diagnosis and management of suspected pump thrombus. J Heart Lung Transplant 2013; 32: 667-670. PMID: 23796150 285. Pagani FD, Miller LW, Russell SD, et al. HeartMate II Investigators. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol 2009; 54: 312-321. PMID: 19608028 286. Kumar A. Optimizing antimicrobial therapy in sepsis and septic shock. Crit Care Clin 2009; 25: 733-751. PMID: 19892250 287. Simon D, Fischer S, Grossman A, et al. Left ventricular assist device-related infection: treatment and outcome. Clin Infect Dis 2005; 40: 1108-1115. PMID: 15791509 288. Saito S, Matsumiya G, Sakaguchi T, et al. Fifteen-year experience with Toyobo paracorporeal left ventricular assist system. J Artif Organs 2009; 12: 27-34. PMID: 19330502 289. Kawata M, Nishimura T, Hoshino Y, et al. Negative pressure wound therapy for left ventricular assist device-related mediastinitis: two case reports. J Artif Organs 2011; 14: 159-162. PMID: 21347682 290. Kinoshita O, Nishimura T, Kawata M, et al. Vacuum-assisted closure with Safetac technology for mediastinitis in patients with a ventricular assist device. J Artif Organs 2010; 13: 126-128. PMID: 20376513 291. Kimura M, Nishimura T, Kinoshita O, et al. Successful treatment of pump pocket infection after left ventricular assist device implantation by negative pressure wound therapy and omental transposition. Ann Thorac Cardiovasc Surg 2014; 20 Suppl: 842-845. PMID: 23535582 292. Ramey WL, Basken RL, Walter CM, et al. Intracranial hemorrhage in patients with durable mechanical circulatory support devices: Institutional review and proposed treatment algorithm. World Neurosurg 2017; 108: 826-835. PMID: 28987857 293. Tahir RA, Rotman LE, Davis MC, et al. Intracranial hemorrhage in patients with a left ventricular assist device. World Neurosurg 2018; 113: e714-e721. PMID: 29510276 294. Wong JK, Chen PC, Falvey J, et al. Anticoagulation reversal strategies for left ventricular assist device patients presenting with acute intracranial hemorrhage. ASAIO J 2016; 62: 552-557. PMID: 27347708 295. Wilson TJ, Stetler WR Jr, Al-Holou WN, et al. Management of intracranial hemorrhage in patients with left ventricular assist devices. J Neurosurg 2013; 118: 1063-1068. PMID: 23451903 296. Tanaka KA, Szlam F, Dickneite G, et al. Effects of prothrombin complex concentrate and recombinant activated factor VII on vitamin K antagonist induced anticoagulation. Thromb Res 2008; 122: 117-123. PMID: 17977586 297. Dickneite G. Prothrombin complex concentrate versus recombinant factor VIIa for reversal of coumarin anticoagulation. Thromb Res 2007; 119: 643-651. PMID: 16842841 298. Nassif ME, LaRue SJ, Raymer DS, et al. Relationship between anticoagulation intensity and thrombotic or bleeding outcomes among outpatients with continuous-flow left ventricular assist devices. Circ Heart Fail 2016; 9: e002680. PMID: 27154497 299. Kadono Y, Nakamura H, Saito S, et al. Endovascular treatment for large vessel occlusion stroke in patients with ventricular assist devices. J Neurointerv Surg 2019; 11: 1205-1209. PMID: 31048456 300. Crow S, John R, Boyle A, et al. Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices. J Thorac Cardiovasc Surg 2009; 137: 208-215. PMID: 19154927 301. Suarez J, Patel CB, Felker GM, et al. Mechanisms of bleeding and approach to patients with axial-flow left ventricular assist devices. Circ Heart Fail 2011; 4: 779-784. PMID: 22086831 302. Demirozu ZT, Radovancevic R, Hochman LF, et al. Arteriovenous malformation and gastrointestinal bleeding in patients with the Heart- Mate II left ventricular assist device. J Heart Lung Transplant 2011; 30: 849-853. PMID: 21530318 303. Aggarwal A, Pant R, Kumar S, et al. Incidence and management of gastrointestinal bleeding with continuous flow assist devices. Ann Thorac Surg 2012; 93: 1534-1540. PMID: 22541185 304. Draper KV, Huang RJ, Gerson LB. GI bleeding in patients with continuous-flow left ventricular assist devices: a systematic review and meta-analysis. Gastrointest Endosc 2014; 80: 435-446. PMID: 24975405 305. Joy PS, Kumar G, Guddati AK, et al. Risk factors and outcomes of gastrointestinal bleeding in left ventricular assist device recipients. Am J Cardiol 2016; 117: 240-244. PMID: 26651456 306. Stulak JM, Lee D, Haft JW, et al. Gastrointestinal bleeding and subsequent risk of thromboembolic events during support with a left ventricular assist device. J Heart Lung Transplant 2014; 33: 60-64. PMID: 24021944 307. Uriel N, Pak SW, Jorde UP, et al. Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation. J Am Coll Cardiol 2010; 56: 1207-1213. PMID: 20598466 308. Meyer AL, Malehsa D, Bara C, et al. Acquired von Willebrand syndrome in patients with an axial flow left ventricular assist device. Circ Heart Fail 2010; 3: 675-681. PMID: 20739614 309. Crow S, Chen D, Milano C, et al. Acquired von Willebrand syndrome in continuous-flow ventricular assist device recipients. Ann Thorac Surg 2010; 90: 1263-1269. PMID: 20868825 310. Geisen U, Heilmann C, Beyersdorf F, et al. Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease. Eur J Cardiothorac Surg 2008; 33: 679-684. PMID: 18282712 311. Bartoli CR, Dassanayaka S, Brittian KR, et al. Insights into the mech-